CURRENT PROBE CT6700
10× the Sensitivity of Conventional Probes Deliver Precise Measurement of Low Current Waveforms from 1 mA
• DC to 50 MHz (-3dB) • 5 Arms maximum • 1 V/A output • φ 5 mm (0.20 in) core dia.
| |
CURRENT PROBE CT6701
10× the Sensitivity of Conventional Probes Deliver Precise Measurement of Low Current Waveforms from 1 mA
• DC to 120 MHz (-3dB) • 5 Arms maximum • 1 V/A output • φ 5 mm (0.20 in) core dia.
| |
CLAMP ON PROBE 3273-50
• DC to 50MHz (-3dB) • 30Arms maximum input • 0.1V/A output • φ 5 mm (0.20 in) core dia.
| |
POWER SUPPLY 3272
• For Hioki wide bandwidth current probes • 3269: Connect up to four sensors • 3272: Single sensor connectable
| |
POWER SUPPLY 3269
• For Hioki wide bandwidth current probes • 3269: Connect up to four sensors • 3272: Single sensor connectable
| |
CLAMP ON PROBE 3276
• DC to 100MHz (-3dB) • 30Arms maximum input • 0.1V/A output • φ 5 mm (0.20 in) core dia.
| |
CLAMP ON PROBE 3275
• DC to 2MHz (-3dB) • 500Arms maximum input • 0.01V/A output • φ 20 mm (0.79 in) core dia.
| |
CLAMP ON PROBE 3274
• DC to 10MHz (-3dB) • 150Arms maximum input • 0.01V/A output • φ 20 mm (0.79 in) core dia.
|
Current Sensors, DC to 3.5 MHz
AC/DC CURRENT PROBE CT6846
• DC to 20 kHz • 1000 A AC/DC rated • 2 mV/A output • φ 50 mm (1.79 in) core dia.
| |
AC/DC CURRENT BOX PW9100
• Current measurement option for PW6001/ 3390/ 3390-10 • Wide-band DC to 3.5MHz, 50A AC/DC rated input, 0.04V/A output • PW9100-03 : 3 channels • PW9100-04 : 4 channels
| |
AC/DC CURRENT SENSOR CT7631
・ DC to 10kHz (-3dB) ・Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.
| |
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
2000 A AC/DC Detachable Current Sensor System that Delivers Stable, Long-term, and Accurate Measurements in Dramatically Changing Environments
・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (1.30 in) core dia.
| |
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
600 A AC/DC Detachable Current Sensor System that Delivers Stable, Long-term, and Accurate Measurements in Dramatically Changing Environments
・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・1mV/A output ・φ 33 mm (1.30 in) core dia.
| |
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
100 A AC/DC Detachable Current Sensor System that Delivers Stable, Long-term, and Accurate Measurements in Dramatically Changing Environments
・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.
| |
AC/DC CURRENT SENSOR CT7642
・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (1.30 in) core dia.
| |
AC/DC CURRENT SENSOR CT7636
・ DC to 10kHz (-3dB) ・Rated 600 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.
| |
DISPLAY UNIT CM7290
• Use with CT7600s/7700s • DCA, ACA, (DC+AC)A, frequency • Output: WAVE, RMS, PEAK, Hz • Power supply for single sensor
| |
AC/DC CURRENT PROBE CT6845
• DC to 100 kHz • 500 A AC/DC rated • 4 mV/A output • φ 50 mm (1.79 in) core dia.
| |
AC/DC CURRENT PROBE CT6844
• DC to 200 kHz • 500 A AC/DC rated • 4 mV/A output • φ 20 mm (0.79 in) core dia.
| |
AC/DC CURRENT PROBE CT6841
• Frequency characteristics DC to 1 MHz, 20A AC/DC rated, 0.1 V/A output • φ 20 mm (0.79 in) core dia.
| |
AC/DC CURRENT PROBE CT6843
• Frequency characteristics DC to 500 kHz, 200A AC/DC rated, 0.01 V/A output • φ 20 mm (0.79 in) core dia.
| |
SENSOR UNIT CT6590
• Voltage output for CT9691/9692/9693 • Power supply for a single sensor
| |
CLAMP ON AC/DC SENSOR CT9691
• DC to 10 kHz (-3dB) • 100 A AC/DC rated input • 200 mV/f.s. output via the CT6590 • φ 35 mm (1.30 in) core dia.
| |
CLAMP ON AC/DC SENSOR CT9692
• DC to 20 kHz (-3dB) • 200 A AC/DC rated input • 200 mV/f.s. output via the CT6590 • φ 33 mm (1.30 in) core dia.
| |
CLAMP ON AC/DC SENSOR CT9693
• DC to 15 kHz (-3dB) • 2000 A AC/DC rated input • 200 mV/f.s. output via the CT6590 • φ 55 mm (2.17 in) core dia.
| |
AC/DC CURRENT SENSOR CT6865
• DC to 20kHz • Phase: DC to 1kHz • Rated 1000A • 2V/1000A output • φ 36 mm (1.42 in) core dia.
| |
AC/DC CURRENT SENSOR CT6863
• DC to 500 kHz, Phase: DC to 300kHz • Rated 200A • 2V/200A output • φ 24 mm (0.94 in) core dia.
| |
AC/DC CURRENT SENSOR CT6862
• DC to 1MHz, Phase: DC to 300kHz • Rated 50A • 2V/50 A output • φ 24 mm (0.94 in) core dia.
| |
SENSOR UNIT 9555-10
• Power supply for current sensors when used alone
| |
CLAMP ON SENSOR 9272-10
1 to 100 kHz/20-200A AC Current Probe for Measuring Inverter Equipment and Other Low Frequency Devices
• 1Hz to 100kHz • Phase: 5Hz to 50kHz • Rated 20A or 200A • 2V/20A, 2V/200A output • φ 46 mm (1.81 in) core dia.
| |
AC/DC CURRENT SENSOR 9709
• DC to 100kHz • Phase: DC to 100kHz • Rated 500A • 2V/500A output • φ 36 mm (1.42 in) core dia.
|
AC Current Sensors, up to 50 kHz
AC FLEXIBLE CURRENT SENSOR CT7040 series
• 10 Hz to 50 kHz (±3dB) • 600A or 6000A AC rated • φ 254 mm (10.00 in) loop dia. to φ 100 mm (3.94 in), 3 loop diameters
| |
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input • 500 mV/f.s. output • φ 100 mm (3.94 in) core dia. to φ 254 mm (10.00 in), 3 loop diameters
| |
CLAMP ON LEAK SENSOR 9675
• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ 30 mm (1.18 in) core dia.
| |
CLAMP ON LEAK SENSOR 9657-10
• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ 40 mm (1.57 in) core dia.
| |
CLAMP ON SENSOR 9695-03
• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 100A AC rated input • 1mV AC/A output • φ 15 mm (0.59 in) core dia.
| |
CLAMP ON SENSOR 9695-02
• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 50A AC rated input • 10mV AC /A output • φ 15 mm (0.59 in) core dia.
| |
CLAMP ON SENSOR 9694
• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 5 A AC rated input • 10 mV AC / A output • φ 15 mm (0.59 in) core dia.
| |
CLAMP ON SENSOR 9669
• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 1000A AC rated input • 0.5mV AC/A output • φ55 mm (2.17 in) core dia.
| |
CLAMP ON SENSOR 9661
• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 500A AC rated input • 1mV AC/A output • φ 46 mm (1.81 in) core dia.
| |
CLAMP ON SENSOR 9660
• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 100 A AC rated input • 1 mV AC / A output • φ 15 mm (0.59 in) core dia.
|
Load Current Sensors
CLAMP ON PROBE 9132-50
Multi-range 1000A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment
• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • 0.2 V AC/range output • φ 55 mm (2.17 in) core dia.
| |
CLAMP ON PROBE 9018-50
Multi-range 500A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment.
• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • 0.2V AC/range output • φ 46 mm (1.81 in) core dia.
| |
CLAMP ON PROBE 9010-50
• Use for level measurement • 40 Hz to 1 kHz • 10 to 500 A AC • 0.2 V AC/range output • φ 46 mm (1.81 in) core dia.
| |
CLAMP ON SENSOR 9650
100A Current Output Sensor for Measuring Load Current with Models 8205-10 and 8206-10 Micro HiLoggers
• 40Hz to 1kHz • 100 A AC (primary) • 100 mA AC (secondary) • 130 A AC max. input • φ 15 mm (0.59 in) core dia.
| |
CLAMP ON SENSOR 9651
500A Current Output Sensor for Measuring Load Current with Models 8205-10 and 8206-10 Micro HiLoggers
• 40Hz to 1kHz • 500A AC (primary) • 500mA AC (secondary) • 600A AC max. input • φ 46 mm (1.81 in) core dia.
|