| Function | Range | Resolution | Measuring Range | Accuracy |
Earth resistance Auto range | 20Ω | 0.01Ω (*) | 0.00 - 20.99Ω | |±1.5%±0.05Ω |
| 200Ω | 0.1Ω | 16.0 - 99.9Ω | |±2%±0.5Ω |
| 100.0 - 209.9Ω | |±3%±2Ω |
| 1500Ω | 1Ω | 160 - 399Ω | |±5%±5Ω |
| 400 - 599Ω | |±10%±10Ω |
| 10Ω | 600 - 1580Ω | --- |
AC current (50Hz/60Hz) Auto range | 100mA | 0.1mA | 0.0 - 104.9mA | |±2%±0.7mA |
| 1000mA | 1mA | 80 - 1049mA | |±2% |
| 10A | 0.01A | 0.80 - 10.49A |
| 30A | 0.1A | 8.0 - 31.5A |
| Operating indication |
| Earth resistance function: |
| Constant voltage injection Current detection (Frequency: Approx. 2400Hz) Dual Integration |
|
| AC current function: Successive approximation |
|
| Over-range indication | "OL" is displayed when input exceeds the upper limit of a measuring range |
| Response time | Approx. 7 seconds (Earth resistance) Approx. 2 seconds (AC current) |
| Sample rate | Approx. 1 time per second |
| Power source | LR6/R6 (AA) (1.5V) × 4 |
| Current consumption | Approx. 90mA (max. 140mA) |
| Measurement time | Approx. 21 hours (when LR6 is used) Approx. 5 hours (when R6 is used) |
| Auto power-off | Turns power off about 10 minutes after the last button operation |
| Applicable standards | IEC 61010-1 CAT IV 300V Pollution degree 2 IEC 61010-2-032, IEC 61326-2-2 (EMC) |
| Withstand voltage | AC 5320Vrms/5 seconds Between the Transformer jaws fitted parts and case enclosure (except for jaws) |
| Conductor size | Approx. φ32mm |
| Dimension | 246 (L)×120 (W)×54 (D) mm |
| Weight | Approx. 780g (including batteries) |
| Accessories | 8304 (Resistors for operation check) 9167 (Carrying case [Hard]) LR6 (AA) × 4, Instruction manual |