Kamis, 03 Maret 2016

KYORITSU 6010A Multi Function Testers

Multi Function Testers

MODEL6010A
 
 
Continuity and Insulation Testing
Live circuit warning LED:
Immediate illumination of a warning lamp if the circuit under test is live
Auto Discharge:
Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
Integral overload protection on internal continuity and insulation test circuitry
Autoranging
500V DC test voltage for insulation tests
200mA short circuit current on continuity ranges
  
6010A
CE
Loop and RCD Testing
Wiring connection check LED’s:
Immediate indication if wiring of circuit under test is correct
Overheat Protection:
Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
Supply Voltage Indication:
Can display supply voltage value in loop impedance mode
Low Current Loop Impedance Test:
Short duration low test current will prevent tripping of many passive RCDs
Auto Data Hold:
Retains displayed reading for set period following test
Phase Angle Selection:
Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs
 
Continuity Testing
Measuring Ranges0 - 19.99 and 10.0 - 199.9Ω (2 auto ranges)
Open Circuit Voltage> 4V (as per IEC 364)
Short Circuit Current> 200mA DC (as per IEC 364)
Accuracy|±(3% + 3dgt)
Loop Impedance Testing
Rated Voltage230V AC +10%-15% (50Hz)
Voltage Measuring Range100-250V AC (50Hz)
Impedance Range
Nominal Test Current
20/2000Ω
25A (20Ω range) 15mA (2000Ω range)
Test Period1/2 cycle (10ms)
Accuracy20Ω range : ±(3% + 8dgt)   2000Ω range : ±(3% + 8dgt)
Insulation Testing
Measuring Ranges0 - 19.99 and 10.0 - 199.9MΩ (2 auto ranges)
Test Voltage500V DC
Output Voltage on
Open Circuit
570V DC±6%
Rated Current> 1mA (as per IEC 364)
Accuracy|± (3% + 3dgt)
RCD Testing
Rated Voltage230V AC +10%-15% (50Hz)
Trip Current SettingsRCD × 1/2: 5, 15, 50, 150, 250mA
RCD × 1: 10, 30, 100, 300, 500mA
Trip Current DurationRCD × 1/2 × 1: 2000ms
Fast Trip150mA
AccuracyTrip current ±3% of test current at 230V.
Trip time ±(3% + 3dgt)
General
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557
Withstand Voltage4000V AC for 1 minute
Power SourceR6 (AA) (1.5V) × 8
Dimensions175(L) × 115(W) × 86(D)mm
Weight780g approx.
Accessories7122B (Test leads) 
KAMP10
* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
R6 (AA) × 8
Instruction Manual
Optional7133B (Distribution board test leads)
*KAMP10(EU): European SHUKO plug
KAMP10(UK): British plug(13A)
KAMP10(AU): Australian plug
KAMP10(SA): South African plug

Tidak ada komentar: