| | Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less | | |
| | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Rated voltage | | | | 500V | | | | 1000V | | | | 2500V | | | | 5000V | | | | 10000V | | | | 12000V | | |
| | | | | | | | | | | | | | | | |
| | |
| | | | Max measurement value | | | | 500GΩ | | | | 1TΩ | | | | 2.5TΩ | | | | 5TΩ | | | | 35TΩ | | |
| | | | | | | | | | | | | | |
| | |
| | | | | | | | | | | | | | |
| | | | Accuracy | | | | 400k - 50GΩ ±5%rdg±3dgt (*) | | | | 800k - 100GΩ ±5%rdg±3dgt | | | | 2M - 250GΩ ±5%rdg±3dgt | | | | 4M - 500GΩ ±5%rdg±3dgt | | | | 8M - 1TΩ ±5%rdg±3dgt | | |
| | | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | |
| | | | | 50G - 500GΩ ±20%rdg (*) | | | | 100G - 1TΩ ±20%rdg | | | | 250G - 2.5TΩ ±20%rdg | | | | 500G - 5TΩ ±20%rdg | | | | 1T - 10TΩ ±20%rdg | | |
| | | | | | | | | |
| | | | | | | |
| | | | | | | | | |
| | | | | | | | | 10T - 35TΩ Values are displayed, but accuracy isn't guaranteed | | |
| | | | | | | | | | | | | | |
| | |
| | | | | | |
| | | | Short circuit current | | | | Max 5.0mA | | |
| | | | | | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Load resistor to output rated voltage | | | | 0.5MΩ or more | | | | 1MΩ or more | | | | 2.5MΩ or more | | | | 5MΩ or more | | | | 20MΩ or more | | | | 24MΩ or more | | |
| | | | | | | | | | | | | | | | |
|
| | |
| | Output voltage | | |
| | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Rated voltage | | | | 500V | | | | 1000V | | | | 2500V | | | | 5000V | | | | 10000V | | | | 12000V | | |
| | | | | | | | | | | | | | | | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Monitor accuracy | | | | ±10%±20V | | | | ±10%±20V | | | | ±10%±20V | | | | ±10%±20V | | | | ±10%±20V | | | | ±10%±20V | | |
| | | | | | | | | | | | | | | | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Output accuracy | | | | 0 - +20% | | | | 0 - +10% | | | | 0 - +10% | | | | 0 - +10% | | | | -5 - +5% | | | | -5 - +5% | | |
| | | | | | | | | | | | | | | | |
| | |
| | | | | | | | | | | | | | | | |
| | | | Selectable range | | | | 50 - 600V (in steps of 5V) | | | | 610 - 1200V (in steps of 10V) | | | | 1225 - 3000V (in steps of 25V) | | | | 3050 - 6000V (in steps of 50V) | | | | 6100 - 10000V (in steps of 100V) | | | | 10100 - 12000V (in steps of 100V) | | |
| | | | | | | | | | | | | | | | |
|
| | |
| | Voltage measurement | | |
| | |
| | |
| | | | | | |
| | | | Measuring range | | | | DCV : ±30 - ±600V, ACV : 30 - 600V (50/60Hz) | | |
| | | | | | |
| | |
| | | | | | |
| | | | Accuracy | | | | ±2%rdg±3dgt | | |
| | | | | | |
|
| | |
| | Current measurement | | |
| | |
| | |
| | | | | | |
| | | | Measuring range | | | | 5.00nA - 2.40mA (Depending on the insulation resistance) | | |
| | | | | | |
|
| | |
| | Capacitance measurement | | |
| | |
| | |
| | | | | | | | |
| | | | Measuring range | | | | 5.0nF - 50.0µF | | | | 5.0nF - 1.0µF (display range: 5.0nF - 50.0µF) | | |
| | | | | | | | |
| | |
| | | | | | |
| | | | Accuracy | | | | ±5%rdg±5dgt | | |
| | | | | | |
|
| | |
| | General | | |
| | |
| | |
| | | | | | |
| | | | Withstand voltage | | | | AC8770V : between line terminal and enclosure / 5sec (50/60Hz) AC6880V : between the measuring terminal and enclosure / 5sec (50/60Hz) AC2330V : between the power connector and enclosure / 5sec (50/60Hz) | | |
| | | | | | |
| | |
| | | | | | |
| | | | Operating temperature & humidity range | | | |
-10ºC - 50ºC / | Relative humidity 85% or less (when operating with an external power supply, no condensation) |
0ºC - 40ºC / | Relative humidity 85% or less (when operating with battery, no condensation) |
| | |
| | | | | | |
| | |
| | | | | | |
| | | | Storage temperature & humidity range | | | | -20ºC - 60ºC / Relative humidity 75% or less (no condensation) | | |
| | | | | | |
| | |
| | | | | | |
| | | | Applicable standards | | | | IEC 61010-1 CAT IV 600V Pollution degree 2, IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed. | | |
| | | | | | |
| | |
| | | | | | |
| | | | Power source | | | | Rechargeable Lead storage battery (12V)* Charging time: approx. 8 hours / AC Power supply (100V - 240V, 50/60Hz)
* Continuous measuring time:
approx. 4 hours |
(a load of 100MΩ at the Insulation resistance 12000V Range.) |
|
approx. 2 hours |
(Max current consumption in range while rated currents are maintained.) |
| | |
| | | | | | |
| | |
| | | | | | |
| | | | Dimension | | | | 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case | | |
| | | | | | |
| | |
| | | | | | |
| | | | Weight | | | | 9kg approx. (including battery) *Instrument and Hard case | | |
| | | | | | |
| | |
| | | | | | |
| | | | Accessories | | | | 7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe), 7227A (Line probe with alligator clip), 8029 (Extension prod), 8212-USB-W (USB adaptor with KEW Windows (Software)), Instruction manual | | |
| | | | | | |
| | |
| | | | | | |
| | | | Optional | | | | 7254 (Longer Line probe with alligator clip) | | |
| | | | | | |
|
Tidak ada komentar: