 |  | RPE 20Ω Protective Conductor Resistance Test |  |  |
 |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Measuring range |  |  |  | 0 - 15.00Ω |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Resolution of measurement |  |  |  | 10mΩ |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Open circuit voltage |  |  |  | < AC 12V |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Measuring current |  |  |  | 10A AC nominal value |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Accuracy |  |  |  | ±3%rdg±5dgt |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |
 |  | RINS 200MΩ Insulation Resistance |  |  |
 |  |  |
 |  |  |
 |  |  |  |  |  |  |  |  |
 |  |  |  | Rating |  |  |  | 250V/20MΩ |  |  |  | 500V/20MΩ |  |  |
 |  |  |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Measuring range |  |  |  | 0 - 19.99Ω |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Resolution of measurement |  |  |  | 10kΩ |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |  |  |
 |  |  |  | Output voltage |  |  |  | 250V DC (+20%/-10%) @1MΩ |  |  |  | 500V DC (+20%/-10%) @1MΩ |  |  |
 |  |  |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Short circuit current |  |  |  | 2.5mA DC or less |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Accuracy |  |  |  | ±2%rdg±3dgt |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |
 |  | Leakage Current Test |  |  |
 |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Measuring range |  |  |  | AC 0.1 - 19.99mA |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Resolution of measurement |  |  |  | 0.01mA |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Examination time |  |  |  | Max 15 seconds |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Accuracy |  |  |  | ±3%rdg±5dgt |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |
 |  | AC VOLT Mains Voltage Check |  |  |
 |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Measuring range |  |  |  | 207 - 264V |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Resolution of measurement |  |  |  | 1V |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Accuracy |  |  |  | ±2%rdg±3dgt |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |  |  |
 |  | Supply voltage |  |  |  | 240V±10% |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Frequency |  |  |  | 50Hz±1% |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Applicable standards |  |  |  | IEC 61010-1 CAT III 300V Pollution Degree2 IEC 61326-1 (EMC) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Dimensions |  |  |  | 185 (L) × 167 (W) × 89 (D) mm |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Weight |  |  |  | 1.2kg (only the instrument body) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Accessories |  |  |  | 7123 (Power cord [AU]) 7129A (Test leads with alligator clip) 7161A (Flat test prod [black]) 7140 (Adapter for exntesion cord) 9147 (Cord case) 9121 (Shoulder strap) Instruction manual |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Optional |  |  |  | 7121B (Distribution board test leads) |