Selasa, 01 Maret 2016

KYORITSU 3125 High Voltage Insulation Tester

High Voltage Insulation Tester

MODEL3125
 
Selection GuideProduct CatalogueInstruction Manual
 

Wide range measurements from 500V to 5000V and up to 1000GΩ.
Large digital display with Bar Graph indication and back light.
Polarization Index measurement (PI).
Timer measurement function.
Indication of Output voltage and Discharge voltage.
Auto-discharge function and Voltage output warning function.
Auto power off and Battery Check.
Safety standard IEC 61010-1 CAT III 600V

Backlight3125 500V/1000V/2500V/5000V
3125
CEAUTO DISCHARGE
RangeInsulation resistanceVoltage
measurement
500V1000V2500V5000VAC/DC V
Measuring range0.0 - 99.9MΩ
100 - 999MΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 1.99GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
100 - 1000GΩ
(1TΩ)
30 - 600V
AC/DC
[50/60Hz]
Accuracy|±5%rdg|±3dgt|±5%rdg|±3dgt|±5%rdg|±3dgt|±5%rdg|±3dgt
|±20%(100GΩ or more)
|±2%rdg|±3dgt
Short Circuit Current1.3mA approx.-------
Rated test Current1mA to 1.2mA
at 0.5MΩ load
1mA to 1.2mA
at 1MΩ load
1mA to 1.2mA
at 2.5MΩ load
1mA to 1.2mA
at 5MΩ load
-------
Open circuit voltage500VDC
+30%
-0%
1000VDC
+20%
-0%
2500VDC
+20%
-0%
5000VDC
+20%
-0%
-------
Maximum display999 Counts (1000 counts only at 1000GΩ)630 Counts
Current consumptionAbout 1000mA (During measurement)110mA approx.
Withstand Voltage
Safety standard
5320V AC for 5 seconds
IEC 61010-1 CAT III 600V, pollution Degree 2
Power supplyDC12V : R14×8
Dimensions205(L) × 152(W) × 94(D)mm
Weight1.8kg approx.
Accessories7165A (Line probe)
7224A (Earth cord)
7225A (Guard cord)
8019 (Hook type prod)
9159 (Carrying case [Hard])
LR14×8pcs (Alkaline battery size)
Instruction Manual
Optional7168A (Line probe with alligator clip)
7253 (Longer Line probe with alligator clip)
8302 (Adaptor for recorder)

Tidak ada komentar: