 |  |  |  | KEW 5010 |  |  |  | KEW 5020 |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |  |  |  |  |
 |  | Recording Mode |  |  |  | Normal, Trigger, Capture |  |  |  | Normal, Trigger, Capture, Power Quality Analysis |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |  |  |
 |  | Operating System |  |  |  | Successive Approximation (CH1 single synchronized sampling) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Rated max. working voltage |  |  |  | AC 9.9Vrms, 14V peak value |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Number of input channel |  |  |  | 3ch |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Measuring method |  |  |  | True RMS |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | RMS measuring interval |  |  |  | approx. 100ms |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Sampling interval |  |  |  |  |
 |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  |  |  | Normal/Trigger mode |  |  |  | approx. 1.65ms/CH |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  |  |  | Capture mode |  |  |  | approx. 0.55ms (waveform: at every 1.1ms) |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |  |  |
 |  |  |  |  |  | P.Q.A. mode |  |  |  | - |  |  |  | approx. 0.55ms |  |  |
 |  |  |  |  |  |  |  |  |
 |
 |  |  |  |  |
 |  | Low battery warning |  |  |  | Battery mark display (in 4 levels) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Over-range indication |  |  |  | "OL" mark is displayed when exceeding the measuring range |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Auto power off |  |  |  | Power-off function operates automatically after a switch remains for 3min. (when recording is stopped) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Location for use |  |  |  | Indoor use, Altitude up to 2000m |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Operating temperature & humidity range |  |  |  | -10ºC - 50ºC / Relative humidity 85% or less (no condensation) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Battery |  |  |  | DC6V: Alkaline battery (LR6) ×4pcs / External supply DC9V (Special AC Adapter) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Possible measurement time |  |  |  | Approx. 10 days (with alkaline LR6 batteries) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Applicable standards |  |  |  | IEC 61010-1:2001 CAT III 300V Pollution degree2 IEC 61326 (EMC standard) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Withstand voltage |  |  |  | AC 3540V (RMS 50/60Hz) / for 5 sec. |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Dimension |  |  |  | 111(L)×60(W)×42(D)mm |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Weight |  |  |  | Approx. 265g |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Accessories |  |  |  | Alkaline battery LR6×4pcs, 9118 (Carrying case) PC software "KEW LOG Soft 2", 7148 (USB cable) Instruction manual, Quick manual, Install manual, USB Notice sheet |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Optional |  |  |  | 8146/8147/8148 (Leakage & Load current Clamp Sensor), 8121/8122/8123 (Load current Clamp Sensor), 8129/8130 (Flexible Clamp Sensor), 8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter), 9135 (Carrying bag), 9119 (Hard carry case), 7185 (Extension cable for sensor) |  |  |
 |  |  |  |  |

|