AC/DC CURRENT BOX PW9100
• Current measurement option for PW6001/ 3390/ 3390-10 • Wide-band DC to 3.5MHz, 50A AC/DC rated input, 0.04V/A output • PW9100-03 : 3 channels • PW9100-04 : 4 channels
| |
POWER ANALYZER PW6001
DC, 0.1 Hz to 2 MHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis
• ±0.02% accuracy • Wide-band DC, 0.1 Hz to 2 MHz • DC, or 1P2W to 3P4W • 6 ch/ Clamp input • Max. 12ch by synchronizing two 6-channel models • Measure inverter equipment and analyze motors • Analyze waveforms without an oscilloscope • Ideal for measuring Silicon Carbide (SiC) inverters that demand high precision
| |
POWER ANALYZER 3390-10
DC, 0.5 Hz to 150 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis
• Super precise ±0.1% accuracy • Wide-band DC, 0.5Hz to 150 kHz • DC, or 1P2W to 3P4W • 4 ch/ Clamp input • Measure inverter equipment and analyze motors
| |
POWER ANALYZER 3390
DC, 0.5 Hz to 150 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis
• Wide-band DC, 0.5Hz to 150 kHz • DC, or 1P2W to 3P4W • 4 ch/ Clamp input • Measure inverter equipment and analyze motors
| |
POWER HiTESTER 3193-10
• Wide-band DC, 0.5Hz to 1MHz • DC, or 1P2W to 3P4W • 6ch-Direct or Clamp input
|
Power Meters - 3-phase AC/DC
POWER METER PW3336
2-Channel AC/DC Power Meter for Single-Phase to 3P3W Equipment such as Motors, Inverters, Power Conditioners, and Power Supplies
• 2 ch input, DC, or 1P2W to 3P3W • 1000 V, 65 A max. input • DC, or 0.1 Hz to 100 kHz • ±0.1 % basic accuracy • Direct or clamp input
| |
POWER METER PW3337
3-Channel AC/DC Power Meter for Single-Phase to 3P4W Equipment such as Motors, Inverters, Power Conditioners, and Power Supplies
• 3 ch input, DC, or 1P2W to 3P3W, or 3P4W • 1000 V, 65 A max. input • DC, or 0.1 Hz to 100 kHz • ±0.1 % basic accuracy • Direct or clamp input
|
Power Meters - Single Phase AC/DC
POWER METER PW3335
• Ultra-sensitive standby power measurement • Measure according to IEC 62301 • DC, or 1P2W • Max. input 1000 V, 30 A • DC, or 0.1 Hz to 100 kHz • ±0.1% basic accuracy • Direct or clamp input
| |
AC/DC POWER HiTESTER 3334
• Compliant with the SPECpower® Benchmark • DC, or 1P2W • 300 V, 30 A max. input • DC, or 45 Hz to 5 kHz • ±0.2% basic accuracy • Direct input only
|
Power Meters - Single Phase AC
POWER HiTESTER 3333
Space-Saving Power Meter for Production Line Testing and Inspection of Energy Consumption of Equipment
• 1P2W • 300 V, 30 A max. input • 45 Hz to 5 kHz • ±0.2% basic accuracy • Direct input only
|