Earth Testers

MODEL4102A
 
4102ASoft Case Model
4102A-HHard Case Model
 

The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
Dust and drip proof. (designed to IEC 529 IP54)
Earth resistance value can be read directly from the scale.
Designed to meet IEC 61010-1 safety standard.
Capable of measuring earth voltage.
Small and lightweight. Shock resistant new case material.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Lead wire connection to C and P terminals and proper auxiliary earth resistance can be checked by "OK" lamp. Lead wire connection to C and E terminals is good when "OK" lamp is illuminated.
4102A
CE
4102A Soft Case Model
4102A-H Hard Case Model
4102A Soft Case Model
4102A-H Hard Case Model
 
Measurement
Ranges
Earth Resistance: 0 - 12 Ω/0 - 120 Ω/0 - 1200 Ω
Earth Voltage [50,60Hz]: 0 - 30V AC
AccuracyEarth Resistance: ±3% of full scale
Earth Voltage: ±3% of full scale
Overload ProtectionEarth Resistance: 276V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 276V AC for 1 minute
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557
Applicable StandardsIEC 60529 IP54
Withstand Voltage3700V AC for 1 minute
Power SourceR6 (AA) (1.5V) × 6
Dimensions105(L) × 158(W) × 70(D)mm
Weight600g approx.
Accessories7095A (Earth resistance test leads) × 1set
(red-20m, yellow-10m, green-5m)
8032 (Auxiliary earth spikes) × 1set
7127A (Simplified measurement probe) × 1set
R6 (AA) × 6
Neck strap
Instruction Manual
Carrying Case: 9084 (Soft case)
 9164 (Hard case)
Optional7100A (Precision measurement cord set)

Tidak ada komentar: